BYD Yuan PLUS Unable to AC Charge: High-Voltage Interlock Connector Inspection

BrandBYD 比亚迪Series元PLUSUpdated NaN-NaN-NaN
BYD Yuan PLUS Unable to AC Charge: High-Voltage Interlock Connector Inspection

Fault Background

The Yuan PLUS uses a highly integrated eight-in-one electric drive assembly, with the on-board charger (OBC) function for AC charging also integrated within it. The high-voltage interlock (HVIL) is responsible for confirming that all high-voltage connectors are fully seated before power-up and charging. Its status is determined by the integrated smart front drive, and there is no separate low-voltage interlock wiring harness—the interlock status directly depends on the mechanical latch of the high-voltage connectors. Once a high-voltage plug is not fully seated, the system will refuse to charge. This article dissects a case of "instrument prompts to check on-board charger, unable to AC charge," where the fault point was simply a high-voltage plug that was not fully seated.

AI concept image: technician inspecting the orange high-voltage connector in the front compartment of a Yuan PLUS

Fault Symptom

ItemObservation
Fault descriptionUnable to charge using AC power
Instrument promptPlease check on-board charger fault
DTCP151100: AC-side high-voltage interlock fault (current fault)
Clear and retestAfter clearing DTC, plug in the charging gun and test; fault persists

Cause Analysis

  1. Integrated smart front drive fault—abnormal interlock determination inside the eight-in-one assembly.
  2. Traction battery fault—abnormal high-voltage connection or internal interlock at the battery end.
  3. Wiring harness fault—issue with the high-voltage wiring harness connector.
  4. High-voltage interlock fault—a high-voltage connector is not fully seated, causing the interlock circuit to open.

Diagnostic Procedure

  1. Read DTC to confirm: Use VDS to read the fault; the on-board charger reports P151100 "AC-side high-voltage interlock fault" as a current fault, and there is no software update available—first rule out software factors.
  2. Clear and retest: Clear the DTC, then plug in the charging gun and test; the fault persists—confirming a real hardware interlock issue.
  3. Understand the interlock structure: In the eight-in-one model, the high-voltage interlock is determined by the integrated smart front drive. There are two locations with mechanical interlock on the vehicle: ① the connection between the integrated smart front drive and the AC charging cable; ② the connection between the integrated smart front drive and the traction battery.
  4. Inspect each location: Focus on checking the seating status of the two high-voltage connectors. When checking the multi-in-one side, it was found that the AC charging port connector was not fully seated.
  5. Restore the connection: Re-seat the AC port connector fully, ensuring the latch is locked.
  6. Verify and resolve: Clear the DTC, plug in the charging gun and test; charging returns to normal, and the fault is resolved.

Yuan PLUS AC charging high-voltage interlock circuit

Repair Plan

  1. When encountering a "high-voltage interlock fault," first clear the DTC and retest to distinguish between a real interlock issue and an intermittent false alarm.
  2. Be familiar with the eight-in-one architecture: the interlock is determined by the integrated smart front drive, and the mechanical interlock points are concentrated at two high-voltage connection locations.
  3. Inspect each connector to ensure it is fully seated and the latch is locked; preliminary troubleshooting can be done without disassembly.
  4. After restoring the connection, always clear the DTC and perform a full charging verification to confirm the fault does not recur.

Unable to AC charge diagnostic flowchart

Key Parameter Quick Reference

Inspection ItemRequirementDescription
High-voltage connectorFully seated, latch lockedHalf-seated condition triggers interlock fault
Interlock DTCP151100 AC-side high-voltage interlock faultIf it recurs after clearing, it is a real fault
Mechanical interlock locationsAC charging cable connection, traction battery connectionOnly these two locations on eight-in-one models
Charging gun testCharging current establishes normallyMust be verified by actual test after repair

Safety Warning

  • A high-voltage interlock fault indicates the system is in a protective state. Before inspecting connectors, the vehicle must be powered down and the charging gun unplugged.
  • Do not plug or unplug high-voltage connectors while energized to avoid arcing and damaging terminals.
  • After restoring the connection, ensure the latch clicks into place and perform a pull-back test to prevent delivering the vehicle with a half-seated connector.

Repair Insights

The eight-in-one high integration brings a counterintuitive conclusion: the high-voltage interlock has no independent low-voltage wiring harness; the interlock itself is the mechanical state of the high-voltage plug. So when encountering interlock faults like P151100, don't rush to suspect the controller or wiring harness. Go back to the most basic check—whether every high-voltage connector is truly seated and locked. The more integrated the vehicle, the easier it is to be stumped by a "simple problem": a plug not pushed all the way in can make the entire vehicle refuse to charge.


【This article is for reference only】

Comments

No comments yet.

Log in to comment

⚠️ High-voltage repairs require professional certification; this article is for technical reference only — always follow the OEM service manual.

WeCom Customer Service